HomeMy WebLinkAbout268367_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101104646
PROJECT ADDRESS:
901 W Civic Center Dr Unit# 330
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
II A
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/28/2020
INITIAL REVIEW
10/15/2020
EXPIRATION
3/27/2021
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Sean Nourani
3.
TEL:
(424)365-2070
FAX:
VALUATION: $30,000.00
EMAIL:
architectseannourani@outlook.com
FLOOD ZONE: X-0602320144J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
General and approval requirement
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please return marked up set of drawings with corrections.Please note that mechanical, electrical and plumbing are under a separate plan review and approval. The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet A0.0:General notes: Note referenced to 7-Eleven project – Please coordinate and revise notes accordingly. Applicable Codes: Please update codes to the 2019 code edition. Under Project Data, Site Address – Please clarify the floor of which the tenant improvement is proposed. Scope of Work: Please elaborate the scope of work to describe in detail what are the works are proposing. Sheet A1.1:Detail 1, Accessible parking layout: Please provide/show wheel-stop at parking spaces. Detail 1: Please show/provide detectable warning (truncated dome) between the pedestrian walk and vehicular area (parking). Sheet A2.0:Egress travel distance measuring: The travel distance shall be measured along the wall. Measured diagonally was insufficient. Space with one exist shall be limited to 100-ft travel distance for building with sprinkler.