HomeMy WebLinkAbout269481_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105012 PROJECT ADDRESS: 1123 N Freeman St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/21/2020 INITIAL REVIEW 11/12/2020 EXPIRATION 4/19/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Leticia Portocarrero 3. TEL: (714)721-3412 FAX: VALUATION: $29,000.00 EMAIL: lettyp67@yahoo.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Sheet 1: Job Description: Please include the addition of entry porch. Project Data: Please include the proposed entry porch area. Existing Floor Plan: Please show existing door and front wall to be removed to accommodate new double door. Structural detail sheets and Title 24 Energy calculation: Please number each plan sheet and coordinate with Sheet Index. Reminder: Correct job address. Sheet 2: Double door: At least one leaf of door shall be 32” clear open. Please coordinate and revise plan accordingly. Windows and doors: on the plan, please clearly specify existing (E) vs. new (N) or replaced (R). Sliding door 10: Please specify tempered. Please provide building sections to show building envelope including floor, wall and roof insulation. Structural comments: New ridge line: Please provide detail to show existing roof framings to support new roof. To reduce additional loads onto existing roof, provide purlin and kickers to support new roof. Beam 1 and 3: The distrusted width of roof loading appeared understated. Please verify bearing location of existing roof frames from both side of the new beams. Please revise beams calculations as necessary. Detail 14/5: Please revise detail to specify 6x post to support 5-1/4” x beam. Beam 4: For clarity, please show beam extended to the bearing wall foundation. Front port: please provide 4x ridge beam with king posts support. Lateral resisting system: Interior walls were removed – Please provide lateral resisting system on the left-to-right direction. Foundation: Detail 1/5: Please revise detail to show minimum 18” separation between grade and floor joist. Detail 1/5: Please revise detail to show minimum 18” deep footing. Please provide pad footing at each end of beam #4. Show underfloor space access to existing and new underfloor space.