HomeMy WebLinkAbout267502_3_Corrections.docxPLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104326 PROJECT ADDRESS: 1601 W MacArthur Blvd PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/17/2020 INITIAL REVIEW 10/6/2020 EXPIRATION 2/13/2021 RECHECKS: 1.11/2/2020 PROJECT APPLICANT CONTACT PERSON: 2. Harmon Ward 3. TEL: (714)241-8944 FAX: VALUATION: $50,000.00 EMAIL: hward@musserarchitects.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039)CMU wall adjacent to the property line. Please provide parapet complying with Section 705.11. Revise plans accordingly. 2nd Review Comment: As responded, Exception 4.2 is used – Please show roof assembly and its support protected with minimum one-hour construction. Otherwise, provide parapet complying with Section 705.11. Sheet A3.0: please show header height, and clear ceiling heights. 2nd Review Comment: Building section with ceiling soffit – 7-ft minimum ceiling height is required in vehicular pedestrian areas. Please revise building section to provide minimum 7-ft clear height. (Section 406.2.2)Structural Comments: Reference detail 7/SD-1: Please revise detail to provide minimum 30” height parapet. Please coordinate with architectural plan. 2nd Review Comment: Coordinate with architectural comment above. Reminder:Final plans and calculation shall be stamped, signed and dated by the engineer of record.