HomeMy WebLinkAbout267377_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104303 PROJECT ADDRESS: 313 1/2 S Deming St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/12/2020 INITIAL REVIEW 8/27/2020 EXPIRATION 2/8/2021 RECHECKS: 1.10/22/2020 PROJECT APPLICANT CONTACT PERSON: 2.11/20/2020 Ernest Little 3. TEL: (562)686-1007 FAX: VALUATION: $120,000.00 EMAIL: earnest.midway@gmail.com FLOOD ZONE: A Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. -Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. PLAN CHECK COMMENTS: Soils report comments: All pages. A few of letters and numbers are missing throughout the soils report. Please print complete report and submit 2 copies to the Building Division. Page 2. Seismicity and faulting: the applicable code shall be 2019 California Building Code and ASCE 7-16. The report incorrectly shows ASCE7-19. Please update the report. Structural comments: Sheet S0.1. A few of letters and numbers are missing throughout the soils report. Please print complete report and update the drawing. Elevation Certificate comments: Corrections on the elevation certificate: Revise the lowest adjacent (finished) grade next to ADUbuilding (LAG) to match grading plan. The elevation shows 60.4 feet on section C item C2 (f) should match grading plan. Corrections on the elevation certificate: Revise the highest adjacent (finished) grade next to ADU building (HAG) to match grading plan. The elevation shows 61.3 feet on section C item C2 (g) should match grading plan. No additional comments on the architectural, structural plans and structural calculations.