HomeMy WebLinkAbout270200_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105229 PROJECT ADDRESS: 2329 1/2 N Santiago St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/17/2020 INITIAL REVIEW 12/3/2020 EXPIRATION 5/16/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Chris Salas 3. TEL: (818)426-3891 FAX: VALUATION: $35,000.00 EMAIL: csalas96@aol.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). Sheet A2 & A3: Existing building Please note on plan “FOR REFERENCE ONLY” Sheet A4: On the plan, please show/provide door landing at both exterior doors. Landing shall be minimum 3-ft measured in the direction of travel, and width equal to door opening. Please specify tempered glass for glazing in door and within of 24” of door. Detail 4/A4, one-hour fire-rated wall: Please revise detail show the 5/8” type ‘X’ gypsum board extending to the underside of the roof sheathing. Sheet A5: North Elevation: Stucco wall is required for the one-hour fire-rated wall. Please clarify. Structural Comments: Concrete curb is required at existing garage door to be infilled. Please coordinate and revise foundation wall detail at infilled wall. Detail 11 & 12/S1: please coordinate with fire-rated wall. Additional blocking is required for drywall extending to the underside of roof sheathing. Final plan shall be stamped, signed and dated by the engineer of record.