HomeMy WebLinkAbout270825_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102105442 PROJECT ADDRESS: 611 E Santa Clara Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/10/2020 INITIAL REVIEW 2/3/2021 EXPIRATION 6/8/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Noah Elias 3. TEL: (949)378-5275 FAX: VALUATION: $15,000.00 EMAIL: noah@noahstudios.net FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Plans were incomplete. In order to provide a comprehensive plan review, a complete set of plans and calculations are required. Please provide the following information on the next submittal for plan review: Provide the following design data on the first sheet Occupancy groups (R-3/U) Type of construction (V-B) Floor area per occupancy group, including the existing house and garage Construction shall comply with the 2019 CRC, CBC, CPC, CMC, CEC, California Green Building Code, and California Energy Code. There was no permit record of the Existing Storage structure. Please remove storage structure or provide plans and calculations to legalize the structure. Provide partial floor plan of the existing house to show spaces adjacent to the proposed patio cover and fireplace. Light, ventilation and emergency escape opening required for the existing rooms shall be maintained. Note on plan: All concealed work installed without permits must be exposed for inspection to the satisfaction of the Building Inspector. This includes methods of attachment and all footings, structural members, mechanical, electrical, plumbing and insulation. Elevation: Please show distance between top of fireplace to the highest point of roof within 10-ft of the fireplace. Provide structural framing plans and details, foundation plan and details, and calculation for the proposed Patio and fireplace. Plan review will continue at time of resubmittal and additional comment will be required. Incomplete submittal will delay the plan check process and additional plan check fee may be required. Final plan and calculations shall be stamped, signed, and dated by a California registered civil engineer or licensed architect.