HomeMy WebLinkAbout271492_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102105636 PROJECT ADDRESS: 2446 N Bonnie Brae PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/13/2021 INITIAL REVIEW 3/8/2021 EXPIRATION 7/12/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jim Ishii 3. TEL: (714)417-3850 FAX: VALUATION: $1,500.00 EMAIL: jimishii88@gmail.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2019 California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review. Plan shall be drawn to scale and be legible. Minimum plan size shall be 11”x17” paper. Provide complete site plan with the following information: Location and size of all structures on the lot. Identify all property lines and easement, streets, etc. Provide lot dimensions and dimensions and distance setback from property lines. Distance between main house and accessory structures. Clearly show location of the proposed work (detached trellis structure and CMU wall). Provide the following design data on the first sheet Occupancy groups (R-3/U) Type of construction (V-B) Number of stories. Floor area per occupancy group Construction shall comply with the 2019CRC, CBC, CPC, CMC, CEC, 2019 California Energy Code, and 2019 California Green Building Code. Provide structural plan and details for the proposed detached trellis structure. Provide structural plan, details and calculation for the proposed CMU wall. Final plan and calculation shall be stamped, signed and dated by a California registered civil engineer.