HomeMy WebLinkAbout270121_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101105209
PROJECT ADDRESS:
3300 S Bristol St
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/12/2020
INITIAL REVIEW
11/27/2020
EXPIRATION
5/11/2021
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Scott Horsley
3.
TEL:
(949)274-1011
FAX:
VALUATION: $30,000.00
EMAIL:
horsleys@bv.com
FLOOD ZONE: X-0602320259J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceOn sheet C-3 , show size of the BESS equipment ( dimension, weight) and detail how attached to the H- frame.Provide dimension and weight for the inverter and power pack on the drawings.Provide top view for the anchorage to match the calculation ( Anchorage spacing and number of anchorage)
To pick up the marked –up plan, please contact the plancheck engineer for pick up appointment. To resubmit your drawings, you may drop them off Mon – Thurs from 9:00 am to 12 pm at the South east entrance of the city hall.