HomeMy WebLinkAbout271098_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101105528
PROJECT ADDRESS:
1801 E St Andrew Pl
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B, SPK
OCCUPANCY CLASSIFICATION(S):
B, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/22/2020
INITIAL REVIEW
2/9/2021
EXPIRATION
6/20/2021
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Francis-Paul Dela Cruz
3.
TEL:
(626)586-4021
FAX:
VALUATION: $1,916,277.00
EMAIL:
fpdelacruz@accoes.com
FLOOD ZONE: X-0602320277J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTSPlease indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Separate mechanical drawings from building plan check submittal package OR add a note “reference only” on each sheet of the mechanical plan.Provide a simple site plan including:Show the size, use, occupancy, and type of construction of the existing buildings on the site.Show location of the new AC units.Location and address of the tenant space within the building.Sheet S101 through S104. Specify on plan the new curb/rail weight AND total weight for new units: AC-2B, AC-2C and AC-2D.Sheet S101 through S104. Show demising walls and location of each tenant with address on plan. The AC units are located on top of the multiple tenants in this building.Per mechanical sheet M.102, the curb/rail weighs 2500#. However, in the calculation, it is only design for 1718# on page 3. Please review and clarify.Refer to mechanical sheet M0.02, the curbs are 1875# or 2500 # for all new units. However, the structural plans (Sheet S101 through S104) showing only 1718 # and design for 1718# on page 3. Please clarify the structural drawings and review and revise the structural calculation and design for unit anchorage and justify the existing structural framing and foundation to support the increased weight. Please clearly response.Per item #10, revise and clarify structural calculation page 2. The total new unit assembly weight appears heavier than the existing one.Incorporate detail D1, D1.1, D1.2, D1.3 and S-01.22-22S from structural calculation into structural drawings.Note that if retrofitting existing building structure to support the new AC units is needed, separate building permit will be required for each tenant suite. Please contact Evelyn @ 714-765-5856 for more information before submitting.