HomeMy WebLinkAbout270739_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105414 PROJECT ADDRESS: 1220 1/2 W Second St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/25/2021 INITIAL REVIEW 2/24/2021 EXPIRATION 7/24/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Rubens Calderon 3. TEL: (714)803-4250 FAX: VALUATION: $15,000.00 EMAIL: rubenscalderon@gmail.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet TS: Project address: Please revise plan to provide the half address for the proposed ADU (1220 – 1/2 W. Second Street). Apply to all sheets. Consultant: Remove engineer consultant if it’s not applicable to the project. Note on plan: Mechanical, Electrical and Plumbing are not part of this plan review and approval. They are subject to field inspection. Sheet A-1: Exterior walls locate less than 5-ft from the property line shall be protected with one-hour fire-rated construction. Please show fire-rated wall and provide construction details. Details shall clearly cross-reference onto the plan. Bedroom: 4x4 hung window did not meet emergency escape opening. Please change to a 4x4 slider. Please show/provide a level landing on the exterior side of the new door. Landing shall be 3-ft, measured in the direction of travel and width equal to wall opening. Please provide/show exhaust vent at the kitchen area. Provide/show exhaust fan in bathroom. Bathroom: Water closet shall have 15” to any wall or obstruction on each side of its centerline and 24” clear space in front. Show dimensions on plan. (402.5 CPC) Shower compartment: Shower compartments shall be not less than 1,024 sq. in. and also be capable of encompassing a 30” diameter circle. Show dimensions on plan. (408.6CPC) Glazing note: Please provide SHGC = 0.23, and U-factor = 0.30 max. Sheet A-2: Please show maximum dimension for the roof overhang. Roof projection shall not project into the 2-ft fire separation distance. Sheet T1: Title 24 Compliance form – Prescriptive approach Fenestration: Please revise U-factor to be 0.30 maximum, and SHGC to be 0.23 maximum. Water heater: Plan show tankless water heater – please coordinate and revise accordingly. Sheet S-1: Section A: Please specify radiant barrier is required underside of roof sheathing, per Energy Requirement. The roof plan did not match with building elevation and the existing roof profile. Please coordinate and revise plan accordingly.