HomeMy WebLinkAbout271788_1_Corrections.docxSPC
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101105718
PROJECT ADDRESS:
1224 E Warner Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
UnKnown
OCCUPANCY CLASSIFICATION(S):
UnKnown
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/25/2021
INITIAL REVIEW
4/5/2021
EXPIRATION
7/24/2021
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Alesandra Reed
3.
TEL:
(352)222-2583
FAX:
VALUATION:$200,000.00
EMAIL:
ReddAF@CDMSmith.com
FLOOD ZONE:X-0602320278J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTSThe drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2019 California Building Standards Code with local amendments.Submittal requirements:Scope-of-Work: Show the complete Scope-of-Work on the first sheet per the permit application. Plan review is subject to the Scope-of-Work on the permit application and any work not part of the Scope-of-Work (Project Description) shall be deleted or marked as “Existing”.Building division does not review soils vapor mitigation. Add note to the reference plan “For reference only”. E.g. sheet G-1 and interim measures soils vapor report.Applicable Codes: Add a note that the applicable Codes are: 2019 CBC, 2019 CPC, 2019 CMC, 2019 CEC, 2019 Energy Code, and City of Santa Ana Municipal Code.
Building Code Analysis:
Occupancy type
Construction type (s)
Total area
Number of stories
Fire Sprinkler – type if applicableIn addition to slab construction for equipment anchorage, the proposed canopy construction shall be as part of the geotechnical report. Provide construction recommendations in the geotechnical report.The canopy structure housing the equipment shall be permitted prior to the equipment installation. This cannot be deferred. Submit the structural framing plan, foundation plan, connection details and structural calculation for the canopy. The submittal package shall include, but not limit to, plot plans, architectural plans, elevations, sections, structural plans, structural calculations, energy, CALGreen and etc…Submit structural calculation, plans and anchorage details for the equipment anchorage complying with 2019 CBC and ASCE 7-16.
Remove notes that indicate canopy structure as deferred submittal on all plans.
Submit fully dimensioned plot plan including: (DO NOT use Civil site plan as architectural site plan)
Dimension distances from building(s) to all property lines, street centerlines, and adjacent existing or proposed structures on the site.
Show the size, use, occupancy, and type of construction of all existing buildings on the site.
Show all interior assumed lot lines, any designated flood plains, open space easements or development-restricted areas.
Width of front, rear, and side yards. Clear width is measured from property line to building face or edge of floor overhang or edge of overhang of usable space below roof, canopy, porch, or covered walks.
Type of construction, occupancy Group, fire sprinkler system equipped in the canopy.Accessible parking stalls (CBC 11B-208, 11B-502)Accessible routes within the boundary of the site from public transportation stops, accessible parking and accessible passenger loading zones, and public streets or sidewalks. (CBC 11B-206)All sheets. Remove the note “ Draft-not for construction” on all sheets. CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.On the site plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from proposed canopy in accordance with all applicable codes. If not, the engineer in record shall provide a statement on plan, stating that the proposed canopy will not alter the existing site drainage pattern.Please note that future demolition permit will be required for removing purposed canopy.Building plan check comments:Building plan check is pending due to the unclear scope of work and incomplete submittals. Future plan check corrections may apply after the review.