HomeMy WebLinkAbout270328_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105270 PROJECT ADDRESS: 2010 1/2 N Tamy Ln PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/23/2020 INITIAL REVIEW 12/10/2020 EXPIRATION 5/22/2021 RECHECKS: 1.2/9/2021 PROJECT APPLICANT CONTACT PERSON: 2. Gonzalo Guillen 3. TEL: (714)227-1189 FAX: VALUATION: $15,010.00 EMAIL: gplanos@sbcglobal.net FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.General and InstructionAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). Sheet A-1: It’s an ADU (not an Junior ADU) – Please revise job address to show half address (2010 1/2 Tamy Lane). Apply to all sheets. Sheet A-2: Wall between two living units shall be protected with a minimum one-hour fire-rated wall. Please clearly show on plan and provide construction detail and clearly cross-reference detail onto the plan. 2nd Review Comment: Response was incomplete. One layer of 5/8” type ‘X’ gypsum board shall be provided on each side of wall (both sides) – please revise floor keynote #2 and detail 2/A3 to show 5/8” type ‘X’ on both sides of wall, extended to roof sheathing.