Loading...
HomeMy WebLinkAbout268515_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104695 PROJECT ADDRESS: 1719 S Grand Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: UnKnown OCCUPANCY CLASSIFICATION(S): B, F-2, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/21/2020 INITIAL REVIEW 10/1/2020 EXPIRATION 3/20/2021 RECHECKS: 1.2/25/2021 PROJECT APPLICANT CONTACT PERSON: 2. Mel Brannon 3. TEL: (949)306-4194 FAX: VALUATION: $20,000.00 EMAIL: melbrannonassoc@yahoo.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS 2nd Review Comment: Revised plans are provided – the following comments are required. General and Approval Requirement: All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840)Sheet TS1:Scope of work: Please include the works of accessibility upgrade as required Sheet SP1:It appears that there was no detectable warning provided between the building walkway (pedestrian area) and the parking/driveway (vehicular area). Please provide and show minimum 3-ft wide (measured in the direction of travel) along the zero curb area. Provide enlarged details for clarity and legible. (11B-247.1.2.5)Sheet A1.1: New Drinking fountains: Please provide details to show compliance with Section 11B-602, for both low and high condition. Provide pedestrian protection in accordance with Section 11B-602.9. Roll-up doors cannot be used as a mean of egress (exit door). Please revise plan to show exit doors for the warehouse area. Public phones: Please provide details to show compliance with 11B-704. Disabled Access Compliance Documentation Form Section A: Certification of Full Compliance with the 2019 California Building Code was checked, please show building is fully comply with the 2019 CBC, Chapter 11B, including the existing restrooms. Otherwise, check the appropriate box. Drinking fountains provided at three locations: Two locations would be complied. Please use the extra money to upgrade other noncompliance accessible features, including sanitation facilities. Please revise form and plan accordingly. Sheet S4: Please complete the structural observation form provided on sheet S4.