Loading...
HomeMy WebLinkAbout272836_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105998 PROJECT ADDRESS: 104 E Fourth St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): A-2, B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/26/2021 INITIAL REVIEW 3/7/2021 EXPIRATION 8/25/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Martin Ocampo 3. TEL: (949)373-6423 FAX: VALUATION: $6,500.00 EMAIL: FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - County of Orange Health Department approval on the corrected/final set of drawings ((714)433-6000) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSheet A-1. Add relocating the entrance door to the women’s restroom into the scope of work on plan.Add note to the drawings on all referenced sheets: TS-1 through SD-1. Add note” Reference only”.Sheet A-2. Show square footage on this assembly room where the new bar is added.Sheet A-2. Show occupant load within this room.Sheet A-2. In the new bar, show overall length of the accessible counter section. Minimum 36” long. (11B-902.4)Sheet A-2. In the new bar, revise the entryway width from 30 inches to 32 inches clear width. (CBC 11B-203.9 & 11B-403.5.1)Sheet A-2. Provide accessibility design and detail on the new women’s restroom entrance door–limit threshold = ½” max.; level area 60” in direction of door swing, 48” opposite door swing, 18”(interior) jamb clearance; bottom 10” of door to be smooth, uninterrupted surface, etc. (CBC 11B-404.2.5, 11B-404.2.4, Table 11B-404.2.4.1, 11B-404.2.10)Provide signage for women’s restroom and design and details on plan. Symbols shall comply with the following:Doorways leading to toilet rooms and bathing rooms shall be identified by a geometric symbol complying with 11B-703.7.2.6 Toilet and Bathing Facilities Geometric Symbols. The symbol shall be mounted at 58 inches minimum and 60 inches maximum above the finish floor or ground surface measured from the centerline of the symbol. Where a door is provided the symbol shall be mounted within 1 inch of the vertical centerline of the door. §11B-703.7.2.6(See exception)Women’s toilet and bathing facilities shall be identified by a circle, ¼ inch thick and 12 inches in diameter. The circle symbol shall contrast with the door, either light on a dark background or dark on alight background. §11B-703.7.2.6.2Provide a wall mounted signage to identify women’s restroom. Where a tactile sign is provided at a door, the sign shall be located along the door at the latch side. Signs shall be located so that a clear floor space of 18 x 18 inches minimum, centered on the tactile characters, is provided beyond the arc of any door swing. (CBC 11B-703.4.2 & Figure 11B-703.4.1)Tactile characters on signs shall be located 48” minimum above finish floor, measured from the baseline of the lowest Braille cells and 60” maximum above finish floor, measured from the base line of the highest line of the raised characters. (CBC 11B-703.4.1 & Figure 11B-703.4.1).