Loading...
HomeMy WebLinkAbout273118_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106077 PROJECT ADDRESS: 1320 E Edinger Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/9/2021 INITIAL REVIEW 3/17/2021 EXPIRATION 9/5/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ali Haddad 3. TEL: (818)203-3029 FAX: VALUATION: $20,000.00 EMAIL: ahaddad@mahddp.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A0.0:Project information: Per permit record, the building is about 3000 sq.ft. – Please verify the total building floor area. Plan was incomplete. Plan shall be stamped, signed and dated by a California licensed architect or registered civil engineer (all sheets). Please provide site accessibility requirement complying with chapter 11B, include the following but not limit to: Accessible parking and signageAccessible path of travel from the public sidewalk and from accessible parking to the accessible building entrance. Accessible route shall be 5% maximum, measured in the direction of travel, and 2% maximum cross-slope, with 48” wide minimum. Provide/show detectable warning, etc. Provide complete details and clearly cross-reference onto the plan.Please note on plan: Automatic Fire Sprinkler system is under a separate review and shall be submitted to Orange County Fire Authority for review and approval. Sheet A0.01: Plan was incomplete. Please provide complete floor plan of the building. Partial floor plan is not acceptable. Sheet A1.0 and A2.0:Interior finish shall comply with Chapter 8, CBC. Furnishings or decorative materials of an explosive or highly flammable character shall not be used.Furnishings or other objects shall not be placed to obstruct exits, access thereto, egress therefrom or visibility thereof.Plan was incomplete. Please provide complete floor plan showing all rooms/spaces, and specify the use of space of each room/space. Provide egress plan complying with Chapter 10 CBC, including occupant load calculation, door schedule and door hardware, exit sign, tactile exit sign, travel distance, etc. Provide/show location of accessible restrooms. Restrooms shall be accessible to persons with disabilities and shall comply with Chapter 11B, Division 6. PLANS WERE INCOMPLETE. PLAN REVIEW WILL CONTINUE AT TIME OF RESUBMITTAL AND ADDITIONAL COMMENTS ARE REQUIRED. PLAN CHECK FEE WAS UNDERSTATED AND ADDITIONAL PLAN CHECK FEE IS REQUIRED.