HomeMy WebLinkAbout262290_4_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102102848 PROJECT ADDRESS: 2319 W Russell Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/5/2020 INITIAL REVIEW 3/26/2020 EXPIRATION 4/1/2021 RECHECKS: 1.1/12/2020 PROJECT APPLICANT CONTACT PERSON: 2.2/26/2021 Carlos Tobias 3.3/30/2021 TEL: (714)727-4982 FAX: VALUATION: $50,000.00 EMAIL: tobyc2525@gmail.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. PLAN CHECK COMMENTSPlease fill out part 1 (project information) of the school fee application form and return with next submittal package. A copy of the form is attached with this correction letter and also in the plan check notice email.PC2: Not resolved. No Form is submitted.The architectural designer or architect shall sign ALLarchitectural plans. Sheet A1.1. Show 30-inch clear width for water closet compartments and 24-inch clearance in front of a water closet. (plan shows 36”x24” around the water closet is not correct) Sheet A1.4. Specify ICC approval number: ESR-1475(not AC-438)forasphalt shingle roof coverings on plan. Sheet A1.4. Callout attic vent locations, sizes and types on plans. (CRC R806.2) PC2: Design is incorrect. Please have the architect who prepares the plans contact Wayne Lee @ 714-647-5848 to discuss this item. Please note that the plan review expiration date is 4/1/2021. Revised plans shall be and obtain approval prior to the expiration date. This plan check may not be extended. No corrections on the structural calculation. END OF COMMENTS