HomeMy WebLinkAbout273634_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101106239
PROJECT ADDRESS:
1343 E Wilshire Ave
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830
EMAIL:
aso@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B, SPK
OCCUPANCY CLASSIFICATION(S):
F-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/25/2021
INITIAL REVIEW
5/3/2021
EXPIRATION
9/21/2021
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Claire Gacalore
3.
TEL:
(408)201-4809
FAX:
VALUATION: $14,000.00
EMAIL:
ryan
FLOOD ZONE: X-0602320276J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A0.0Provide note on the title sheet: “Revision drawings (Delta One) include additional 726 square foot of canopy. The original building permit number is 101102197.”Under Scope of Work, revise the floor area of canopy to 8,060 square feet.Under Scope of Work, include two new stairways in front of the canopy structure.Sheet A1.0The accessible route has been redesigned from previous approved set of plan. The site plan shows an “ADA lift” near the adjacent building entrance. An accessible lift is not allowed as a component of an accessible route for new buildings. Revise accessible route design, or keep the original design.Use a dashed or dotted line to show accessible route from the accessible parking space to the new canopy.Provide details on the “3’ deep truncated domes” near the building entrance.Cloud all the changes with Delta-One symbol.Sheet A2.0Detail 3/A4.0 is referenced at the egress door. Provide sheet A4.0.Detail 12/A4.0 is referenced at the stair. Provide detail 12. Detail 12 is empty on the original sheet A4.0.Structural CalculationsStructural calculations were not provided. Provide two sets of revised calculations with the additional floor area included in the structural design.