HomeMy WebLinkAbout270971_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105481 PROJECT ADDRESS: 925 1/2 S Susan St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/17/2020 INITIAL REVIEW 1/21/2021 EXPIRATION 6/15/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Thanh Dang 3. TEL: (714)369-9055 FAX: VALUATION: $97,500.00 EMAIL: thanh@tkconstructionco.com FLOOD ZONE: X-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet A-2.1 & A-2.2: Please provide/show a building cross-section from North-to-South direction to show separation between the two living units. Provide detail to show construction of one-hour fire-rated wall. Show fire-rated wall continuation at 1st floor top plates. Details shall be clearly cross-reference onto the plan. Sheet A-3.1 Provide detail to show separation between ADU and garage. The 5/8” type ‘X’ shall be extended to the roof sheathing. Please revise building section to show R-30 + R-13 insulation in attic, and R15 insulation between garage and ADU. (Per Title 24 Calculation) Sheet A-4.0: 2nd Floor: Please show/provide smoke alarm outside of the sleeping room. Sheet SD2: Detail 5/SD2: Please revise detail to show/provide rafter-ceiling lap nailing.