HomeMy WebLinkAbout259924_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101102114 PROJECT ADDRESS: 20 Civic Center Plz PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: I A, SPK OCCUPANCY CLASSIFICATION(S): B, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/4/2019 INITIAL REVIEW 1/27/2020 EXPIRATION 5/2/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Son Tran OR Robert (714)329-9621 3. TEL: (562)572-5633 FAX: (714)897-2110 VALUATION: $23,000.00 EMAIL: vvdmanagement@vvdcomm.net FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2016 California Building Standards Code with local amendments.All persons preparing plans, specifications, and instruments of service for others shall sign those plans, specifications and other instruments of service for others shall sign those plans, specifications and other instruments of service and all contracts therefore. This requirement applies to both exempt and non-exempt projects. Business and Professions Code Chapter 3, Division 3, Section 5536.1(a).Drawings must be to scale and be on 18” x 24” minimum sheets. - Provide a fully dimensioned Floor Plan Please provide complete floor plan of the parking to show entrance to the building.Separate permit is required for parking spaces restriping , please see permit technicians.Each lot or parking structure where parking is provided for the public as clients, guest or employees, shall provide accessible parking as required by CBC Section 11B-502).CBC Section 11B-502.4, Item 4. Surface slopes of accessible parking spaces shall be the minimum possible and shall not exceed 1 unit vertical to 50 units horizontal (2% slope) in any direction.CBC Section 11B-208.2.4 One in every six accessible spaces, but not less than one, shall be served by an access aisle 8’-0” (96”) wide minimum and shall be designated van accessible as required by Section 11B-502. The words NO PARKING shall be painted on the ground within each eight’ loading and unloading access aisle. This notice shall be painted in white letters no less than 12” high and located so that it is visible to traffic enforcement officials. Electrical Vehicle charging station shall comply with 11B-228.3, when it is provided for Common use , please justify if Exception applies.Show EV station is in compliance with section 11B-812.Show operable parts are in compliance with section 11B-309.“Provide Van accessible and standard accessible electric vehicle charging station per table 11B-228.3.2.1Provide accessible route per 11B-812.5Provide detail for accessible EV charging station per 11B-812.6.1 and 11B-812.6.2Provide clear floor space at EV equipment per 11B-612.3 (minimum 30”x48”)