HomeMy WebLinkAbout273391_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106170 PROJECT ADDRESS: 2001 E First St Unit# 109 PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/17/2021 INITIAL REVIEW 3/28/2021 EXPIRATION 9/13/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jeff Beddow 3. TEL: (949)722-7400 FAX: (949)722-8855 VALUATION: $12,000.00 EMAIL: jeff.saproperties@gmail.com FLOOD ZONE: APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmitted 2 sets of corrected plans.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceAll sheets. Correct the suite number to #109 instead of #160.Submit a letter describing in detail the use of proposed medical building based on chapter 3 occupancy description of CBC for B or I-2.1 occupancy. Please clarify if building is used for outpatient surgery procedure. Include a statement whether or not there will be non-ambulatory patients or medical care that may render ambulatory patients incapable of unassisted self-preservation and the number of each type of patient.The license holder for the proposed OSHPD 3 clinic shall write a letter addressed to the Building Official describing the services to be offered and if the facility is subject to CBC Section 1226. Include a statement whether or not there will be non-ambulatory patients or medical care that may render ambulatory patients incapable of unassisted self-preservation and the number of each type of patient. Clarify use of proposed medical building as I-2.1 or limited to B occupancy only.Sheet T-1. If this is not OSPHD3 project, add note to building data that this is not an OSHPD 3 outpatient clinic.Sheet T-1. Revise general note #4 to indicate the 2019 California Building Code as the governing code.Sheet T-1. Specify the use and occupancy on all neighbor suites and above the suite #109. Provide fire barrier and floor/ceiling assembly between tenants per CBC Table 508.4. Specify __ hour of rated wall or floor/ceiling assembly on plan with approved assembly details called out.Sheet A-1. Provide project address, drawing title and sheet number on sheet A-1.Sheet A-1. On the plan, show 66” width egress are provided along the exit access route to the building exit. (per occupant load table on sheet T-1).Sheet A-1. Provide exit access route on plan from the furthest point (storage room) to the building exit. Justify the maximum common path of travel not to exceed 100 feet and the maximum travel distance not to exceed 200 feet. (Table 1006.2.1 and Table 1017.2)Sheet A-2. Provide and show tactile exit signs complying with Section 11B-703 and in accordance with Section 1013.4 at (1) the new door #2 and all existing exit doors.Sheet A-2. Provide tactile exit sign detail complying with section 11B-703 on plan. The mounting height requirements must be addressed.Sheet A-2. New doors shall be accessible. Provide following requirements on plan: Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 11B-309.4 Operation. Operable parts of such hardware shall be 34 inches minimum and 44 inches maximum above the finish floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides. §11B-404.2.7Interior hinged doors and gates: 5 pounds maximum.Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other and be free of sharp or abrasive edges. Cavities created by added kick plates shall be capped. §11B-404.2.10Sheet A-2. At the new utility sink, cross reference detail 2/A-2 into the sink AND show minimum 18” from the center of the sink to the partition wall on the plan.Sheet A-2. Detail 1. Specify the fasteners at the bottom of the non-bearing partition in the detail. The connection shall be capable to support the minimum 5 psf horizontal force from the tributary area.END OF COMMENTS