HomeMy WebLinkAbout272354_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105867 PROJECT ADDRESS: 2317 1/2 W Bobby Ln PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/10/2021 INITIAL REVIEW 3/10/2021 EXPIRATION 8/9/2021 RECHECKS: 1.4/19/2021 PROJECT APPLICANT CONTACT PERSON: 2. Miriam Pio 3. TEL: (909)246-1204 FAX: VALUATION: $50,000.00 EMAIL: zahaarchdesign1@gmail.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.Instruction and Approval requiredAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet A3: One-hour fire-rated wall is required between two living unit. Please show one-hour wall between the proposed ADU and existing house. Provide detail construction of one-hour wall assembly and clearly cross-reference detail onto the plan. 2nd Review Comment: Response was incomplete. On the plan, please clearly show one-hour wall between the existing house and new ADU. One layer of 5/8” type ‘X’ gypsum board shall be provided on both sides of wall and shall extended from foundation/slab to the underside of roof. ADU shall be provided with at least one egress swing door, with minimum 32” clear opening (3068 door). Sliding door is insufficient. 2nd Review Comment: Window schedule #10 did not match with window size called out on the floor plan. Please coordinate and revise window schedule. Also, please provide tempered glass for living room window located within 24” of door. Sheet S-1: Please provide detail to show shear transfer between the existing roof and plywood shear wall. 2nd Review Comment: Please provide detail shear transfer of new shear wall to existing top plates.