HomeMy WebLinkAbout272997_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106040 PROJECT ADDRESS: 3921 W Crystal Ln PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/4/2021 INITIAL REVIEW 3/16/2021 EXPIRATION 8/31/2021 RECHECKS: 1.4/27/2021 PROJECT APPLICANT CONTACT PERSON: 2. Khoa Nguyen 3. TEL: (714)548-5895 FAX: VALUATION: $25,000.00 EMAIL: Khoavannguyen75@yahoo.com FLOOD ZONE: X-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet A-1: Cool Roof is required per Title 24 Calculation. Please specify CRRC number for the roofing material on the plan. 2nd Review Comment: Please provide the Cool Roof Rating Council (CRRC) number on the plan. Sheet A-4: Energy Mandatory Measures Summary and Green Code notes provided are under the old code edition. Please provide notes to reflect the 2019 California Energy Code, and California Green Code. 2nd Review Comment: Plan must be legible. Please update notes to the current code edition (2019) and revise notes to be legible. Sheet S2: Please provide lateral resisting system at gridline A and B. Please identify what lateral resisting system are used at line A and B, in accordance with ASCE7-16, Table 12.2-1. 2nd Review Comment: Lateral resisting system provided at line A and B were insufficient. Please provide shear wall in compliance with ASCE7-16 and SDPWS. The lateral system must be capable of transfer lateral loads from the roof diaphragm to foundation. Maximum shear wall aspect ratios shall comply with Table 4.3.4 of the SDPWS. 2nd Review Comment: Please comply. 2nd Review Comment: Veneer located above window header height – Please provide structural calculation and attachment details for the veneer. 2nd Review Comment: Please provide structural frame and support details for the new skylight. Sheet S1: New shear wall panel at existing footing: Please provide detail to show anchor bolt retrofit (new anchor to existing footing). 2nd Review Comment: Detail 5 & 6/SD1 were mistakenly called out at the wrong location. Please coordinate and revise detail reference accordingly.