HomeMy WebLinkAbout272042_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105786 PROJECT ADDRESS: 3400 W Maywood Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/1/2021 INITIAL REVIEW 4/6/2021 EXPIRATION 7/31/2021 RECHECKS: 1.5/17/2021 PROJECT APPLICANT CONTACT PERSON: 2. Simon Gwon 3. TEL: (213)446-9234 FAX: VALUATION: $140,000.00 EMAIL: simon@forearchitects.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Reminder: Architect of record shall stamped, signed and dated on each sheet of plans. Sheet A1.0: Parking shall not block the exit door. Please coordinate and revise plan accordingly. Strikeout parking space as “NO PARKING”. Detectable warning: Please provide detail to show 3-ft strip detectable warning complying with 11B-705.1.1 and 11B-705.1.2.2Sheet A1.2: Plan Legend: Please clearly referend to sheet A6.1 for door schedule. Plan shall be stamped, signed and dated by the architect. Wall detail referenced to sheet A6.1 was not applicable. Please revise detail reference to sheet A5.1. Sheet A1.1: Exiting Plan / Egress PlanParking shall not block the exit door. Please coordinate and revise plan accordingly. Please show common path travel distance on the plan – 100-ft maximum (for sprinklered building). Egress shall not pass through an adjoining space, such as storage room, agricultural rooms, dry room, fertilization room, etc. Please revise plan to create a corridor continuous to the exit doorways. Please coordinate and revise floor plan, MEP plans accordingly. Sheet A4.1:Accessible restrooms: Please show door not encroachmore than 12” into the 60” turning circle. The Exception 2 of Section 11B-603.2.3 allow the door swing into the clear floor space but not the turning space required per section 11B-304. Door swing should still maintain clearance for wheelchair turning space. Please show/provide minimum 60” clear floor space for the water closet, measured from the side wall to the edge of the sink. A minimum 60” wide x 48 inches deep maneuvering space shall be provided in front of the water closet. Please coordinate required floor clearances with the actual fixtures dimensions. It appears that the restrooms would not accommodate all the required clearances. (11B-604.3)