Loading...
HomeMy WebLinkAbout273666_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106251 PROJECT ADDRESS: 5105 W First St Unit# 101 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/26/2021 INITIAL REVIEW 4/21/2021 EXPIRATION 9/22/2021 RECHECKS: 1.5/18/2021 PROJECT APPLICANT CONTACT PERSON: 2. Bao Pham 3. TEL: (909)538-7067 FAX: VALUATION: $55,000.00 EMAIL: bao@bdpeng.com FLOOD ZONE: A-0602320256J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet CS-1:On the plan, please show/provide an accessible route from the public sidewalk to the front door (South elevation). Provide details for ramp and handrails. 2nd Review Comment: New ramp detail provided on sheet AS-1 – Detail 2: Top landing adjacent to wall – Door swing at any position shall not reduce the minimum dimension of the ramp landing to less than 42 inches. Please coordinate and revise plan accordingly. (11B-405.7.5) Bottom landing: Please revise plan to provide minimum 6-ft clear landing at the bottom landing of ramp. Please coordinate and revise ramp configuration accordingly. (11B-405.7.3.1)Handrail on both sides of ramp shall be extended 12” horizontally in accordance with 11B-505.10. 2nd Review Comment: Sheet AS-2 –The Disable Access Compliance Documentation would not apply to this project, since this is a newly constructed building and first tenant occupancy T.I. Please omit/delete from plan.