Loading...
HomeMy WebLinkAbout274164_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106412-13 PROJECT ADDRESS: 301 N Garfield St PLAN CHECK ENGINEER: Le, TungTEL:714 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/13/2021 Temporary sale office at the SFD INITIAL REVIEW 4/26/2021 EXPIRATION 10/10/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Frank Chen 3. TEL: (626)203-1456 FAX: VALUATION: $10,000.00 EMAIL: fchen@kbhome.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet TS: Under Code Analysis: Accessibility – Please use 11B for the accessibility requirement at the sale office. Project Information: Sprinkler type 13D does not qualify for travel distance increase. Please revise maximum travel distance accordingly. Please note on plan: Mechanical, Plumbing and Electrical are not part of this plan review and approval. Referenced Grading Plan sheet 2 of 6: the area (sheet 5) at the townhome is not part of this permit application – Please note on plan “Not a part”. Grading Plan sheet 4 of 6: Please show required dimensions for the accessible parking and access aisle. Show accessible van parking space; the accessible aisle shall be located on the passenger side. Grading Plan sheet 4 of 6: Please clearly show location of the accessible restroom. Grading plan sheet 4 of 6: The area outside of the garage door shall be flat (2% slope maximum). Please coordinate and revise plan. Grading plan sheet 5 of 6: This area is not part of this permit application and plan review – Please omit. Sheet S0.1: Please add the following notes onto the plan – The force for pushing or pulling open a door shall be 5-lb maximum. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.Sheet S0.2: Please coordinate with grading plan sheet 4 of 6 for the slope of the door landing on the left door. Ceiling finish: Please provide detail to show ceiling finish material and structural details for the ceiling finish. Grading plans shall be stamped, signed and dated by a licensed civil engineer registered in the State of California.