HomeMy WebLinkAbout273053_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106055 PROJECT ADDRESS: 3400 W Warner Ave Unit# A PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): A-3, B, M, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/5/2021 INITIAL REVIEW 4/16/2021 EXPIRATION 10/2/2021 RECHECKS: 1.05/20/2021 PROJECT APPLICANT CONTACT PERSON: 2. Tatev Oganyan 3. TEL: (818)237-7867 FAX: VALUATION: $30,500.00 EMAIL: tatev@theoganyanagency.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings (647-5839 or 647-5700) - Public Works Agency approval (647-5039)Plan check comments:New corrections based on the revised Sheet A-0.0.0: (E.g. See suite B storage rack cover sheet)Clarify the Type of Construction.Occupancy and Building area: Revise to provide updated justification.Clarify deferred submittal items. They do not match the plan.Clarify the under separate permit items. Show correct information. Revise the scope of work to provide correct description for this permit only.Provide architectural site plan. Plans are stamped and signed by the license architect in responsible charge.Provide architectural floor plan on the inventory room with storage racks. Plans are stamped and signed by the license architect in responsible charge.Provide egress plan on the inventory room with storage racks. Plans are stamped and signed by the license architect in responsible charge. Separate egress plan from sheet MH-001.Verify with OCFA and Fire Prevention Engineer if fire-separation is required from high-pile inventory and the rest of the building. On the current permitted plan (permit: 101105140), it shows non-rated walls at the perimeter of the inventory room #107. If fire-barrier is required, revise plan to show location of the fire-barrier with wall legend call out. Provide rated wall assembly, continuity from the foundation to the roof deck, penetration through rated assembly, and opening protection and cross-referencing to floor plan. Please update floor plans and site plan.Sheet MH-001. Separate egress plan from this plan. Provide and show tactile exit signs complying with Section 11B-703 and in accordance with Section 1013. Show accessibility design and detail on plan.NO RED LINES ON THE DRAWINGS AND CALCULATION.END OF COMMENTS