HomeMy WebLinkAbout269209_4_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104932 - 33 PROJECT ADDRESS: 5117 1/2 W Morningside Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/13/2020 INITIAL REVIEW 11/5/2020 EXPIRATION 4/11/2021 RECHECKS: 1.1/7/2021 PROJECT APPLICANT CONTACT PERSON: 2.6/4/2021 Leon Tran 3. TEL: (714)418-6604 FAX: VALUATION: $75,000.00 EMAIL: trandesign7@gmail.com FLOOD ZONE: A-0602320143J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. -Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). This project is in a special flood hazard area designated on the flood insurance rate map (FIRM) as zone A or AE. This zone requires that the lowest finish floor elevation (including basement) of the structure shall be at (or above) base flood elevation determined by a hydrology study for the A zone, or at (or above) the base flood elevation specified for the AE zone, on the flood insurance rate map. All elevations must be referenced to the National Geodetic Vertical Datum. Reference should be made to the Flood Plain Management Ordinance, Santa Ana Municipal Code, Chapter 7, for complete requirements. Drawings shall show compliance with said ordinance including noting flood zone and finish floor elevation." Note on plans: "A Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE shall be completed by a California Licensed Land Surveyor or California Registered Civil Engineer who is authorized to practice land surveying. The completed ELEVATION CERTIFICATE must be submitted to the Building Inspector at the time of foundation inspection, and a final certificate must be submitted at the time of final inspection." 2nd Review Comment:The Elevation Certificate is incomplete. Please provide hydrology study to for Base Flood Elevation. Complete Elevation Certificate shall be imprinted onto the plan. 3rd Review Comment: Please provide documentations to support the BFE stated in the Elevation Certificate. Provide hydrology study to determine the base flood elevation (BFE). 2nd Review Comment: Please provide the hydrology study along with the Elevation Certificate for review and approval. 3rd Review Comment: Pending comment above. Reminder:Final plans and calculation shall be stamped, signed and dated by the engineer of record. Sheet A1: Wall located within 5-ft of the property line shall be protected with one-hour fire-rated wall. Please provide detail of one-hour rated wall assembly and clearly cross-reference onto the plan. 2nd Review Comment: Please provide construction detail for one-hour fire-rated wall assembly. Detail shall be clearly cross-referenced onto the plan. 3rd Review Comment: Detail 21SD1 provided did not show one-hour fire-rated wall assembly. Please provide detail to show one-hour rated wall. Sheet A2: On the plan, please specify plumbing fixtures flow rates per 2019 California Green Building Code. 2nd Review Comment: Please revise lavatory faucet flow rate to 1.2 gallon per minute. 3rd Review Comment: Plan was not revised. Please comply. 2nd Review Comment: On the floor plan, please clearly show one-hour wall and provide detail construction of one-hour wall assembly. 3rd Review Comment: Please comply. Structural Comments: Provide detail for ceiling-to-ceiling lap connection and clearly cross-reference onto the plan. 2nd Review Comment: ceiling joist is sliced at the interior wall – please show ceiling lap connection. 3rd Review Comment: Please provide detail for ceiling lap/sliced connection. New Patio Cover: Please provide complete structural framing, foundation support, details and structural calculation for the proposed patio cover. 2nd Review Comment: Sheet A5.1 – Provide lateral support for the proposed patio cover. 3rd Review Comment: Please provide lateral support for the patio cover. Provide calculation.