HomeMy WebLinkAbout272727_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101105957 PROJECT ADDRESS: 728 E Dyer Rd PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/24/2021 INITIAL REVIEW 3/6/2021 EXPIRATION 8/23/2021 RECHECKS: 1.6/20/2021 PROJECT APPLICANT CONTACT PERSON: 2.6/30/2021 Randy Orozco 3. TEL: (714)458-6470 FAX: VALUATION: $100,000.00 EMAIL: randy@rpodesigns.com FLOOD ZONE: X-0602320278J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A6: Detail 9/AD4 called out at interior partition wall was not applicable. Please coordinate and revise detail accordingly. Hard ceiling legend referenced to detail 10/AD4 was not applicable. Please coordinate and revise detail accordingly. Provide ceiling fame and detail. Please provide detail for interior partition wall attachment at top and bottom. Details shall be clearly cross-referenced onto the plan. Fire-rated wall at the electrical room – Please provide construction detail of one-hour wall assembly. Show wall extend from foundation to roof sheathing. Clearly cross-reference details onto the plan.Prefabricated Ceiling panel: On the plan, please specify minimum thickness of ceiling panel and check allowable span of panel. It appears that the panels will exceed the allowable.