Loading...
HomeMy WebLinkAbout276963_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 103107206 PROJECT ADDRESS: 2675 W Edinger Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B, M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/13/2021 INITIAL REVIEW 7/24/2021 EXPIRATION 1/9/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Abdulmasih Aboeid 3. TEL: (818)738-3283 FAX: VALUATION: $1,000.00 EMAIL: eddy_aboeid@yahoo.com FLOOD ZONE: X-0602320257J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS General and Instruction All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) Plans were incomplete. The following information are required and plan review will continue at time of resubmittal. Please provide site plan showing property lines, location of building with the proposed work, all buildings located on the same lot, streets, north arrow. Arial map provided were insufficient. Provide/show an accessible path of travel from the public sidewalk to the accessible main entrance; and from the accessible parking space(s) to the accessible main entrance. Accessible path of travel shall be 5% maximum slope, measured in the direction of travel, 2% maximum cross-slope, and minimum 48” wide. Show/provide accessible parking space(s) serving the building. Show location and provide details to show compliance with Section 11B-502. Show curb ramp, detectable warning and etc. along the accessible route. Please provide building analysis: Floor area of the entire buildingFloor area of the tenant spaceOccupancy groups Occupant calculation and occupant loadsType of constructionFire Sprinkler (yes or no)No of storyApplicable Codes (2019 CBC, CMC, CEC, CPC, California Energy Code, etc.)Provide detail scope of work, and clarify whether onsite consumption is provided. Provide a complete floor plan, and show adjacent spaces and demising walls. Partial floor plan was insufficient. Plan shall be drawn to scale. Provide door schedule including door hardware. Provide egress plan. Wall construction: Please provide complete wall construction detail to show fastener of braces/kickers to structural roof above, and specify spacing of the 2x studs. Detail shall be clearly cross-referenced onto the plan. Please provide ceiling plan provide detail. Restroom: Restroom plan showed on plan were not legible and not complied with the current code edition. Please provide restroom plan to show compliance with the Chapter 11B, Division 6. Final plan shall be signed and dated by a the person who’s responsible for preparing construction document. Plan was incomplete. Plan review continue at time of submittal. Additional comments and fee are may be required.