HomeMy WebLinkAbout277041_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101107231 PROJECT ADDRESS: 3321 S Bristol St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, M, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/21/2021 INITIAL REVIEW 7/31/2021 EXPIRATION 1/17/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Cindy Ramirez 3. TEL: (213)858-7896 FAX: VALUATION: $700,000.00 EMAIL: cindy@permitadvisors.com FLOOD ZONE: X-0602320259J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A0.0: Code Data Summary: Please increase font size for legible. Construction Type: Please clarify construction type V-B (nonrated) or V-A (fire-rated). Code Data Summary: Please specify allowable building area per Table 506.2, CBC. Drawing Index: Plumbing, Mechanical and Electrical are under a separate review and approval – Please omit MEP on the Drawing Index. Storage racks and shelves appeared to be under a separate submittal. Please list it under the separate permit items. Sheet SP1.0: ON the plan, please show/provide an accessible route from the public sidewalk to the building primary entrance. On the plan, please show location of accessible Van parking space. Accessible parking spaces: Please provide accessible parking details to show compliance with 11B-502, including dimensions, marking, and signage. Details shall be clearly cross-referenced onto the plan. Sheet G1.4 through G1.6: Please update checklist to 2019 California Green Building Code. Sheet D1.0: Please specify use of space and occupancy groups of the adjacent buildings. Legend: Please revise Sheet X1.0: On the plan, please show (common) travel distance for the processing room. Sheet A1.0: On the plan, please specify exiting fire wall between buildings. On the plan, please show cashier stations and provide details to show compliance with accessibility requirements. Please clarify whether storage racks/shelvesare part of this permit application or under a separate permit. Sheet A2.0: Please show/provide means of egress illumination inside of the building per 1008.1. Sheet A4.0: Please show/provide exterior landing and maneuver space for door 5B. Accessible restrooms: Notes by themselves were incomplete. Please provide accessible restroom details to show compliance with Chapter 11B, Division 6. Accessible toilet: Please show location of water closet per 11B-604.2. Please specify door type for door leading to the restroom hall. Sheet A4.1: Please specify door schedule for double doors at the processing room. Electrical room: Door may require to be equipped with panic hardware. Please specify electrical panel size. Stair referenced to detail 9/ADA-1 was not applicable; sheet ADA-1 was not provided. Please coordinate and revise plan accordingly. On the plan, please show an accessible path of travel from the building to the proposed trash enclosure. Sheet A5.1: Details shall be clearly cross-referenced onto the plan and delete detail that does not apply to the project. Sheet A5.2: Details shall be clearly cross-reference onto the plan and delete detail that does not apply to the project. Plan shall be legible. Please increase font size. Detail 10: Please revise detail to show spout locations in compliance with Section 11B-602. Show dimensions on plan. Structural Review Comments: Structural calculations were not provided. Please provide structural calculation for review and approval. Equipment pad for the proposed compactor: on the plan, please specify maximum weight of the compactor and provide detail anchorage for the compactor machine. Provide calculation. Plan review will continue at time of resubmittal. Additional comments may be required.