Loading...
HomeMy WebLinkAbout275433_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106788 PROJECT ADDRESS: 2500 W MacArthur Blvd PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/3/2021 INITIAL REVIEW 6/9/2021 EXPIRATION 11/30/2021 RECHECKS: 1.06/30/2021 PROJECT APPLICANT CONTACT PERSON: 2. Scott Harmon 3. TEL: (714)622-9394 FAX: VALUATION: $10,000.00 EMAIL: lisa@smoothstoneconstruction.com FLOOD ZONE: X-0602320258J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. PLAN CHECK COMMENTS: All sheets. Provide valid expiration date on the engineering stamp. The license shall not be expired at the time of submittal. Sheet TS-1. Revise type of construction to Type: VB. Sheet TS-1. Provide an Index of drawings on cover sheet. Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Specify the weather protection of the chimney wall on chimney elevations. PC2: No response. Please address this item on plan. Show exterior wall construction assembly. A minimum of one layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt shall be applied over studs of all exterior walls. Specify that two layers of Grade D or 60 minute Grade D paper shall be applied over all wood base sheathing. (CRC R703.2) PC2: No response. Please address this item on plan. Provide roof framing plan to show location of chimney repair and cross-reference applicable structural details (which type of chimney) from sheet S-3 into the roof framing plan. PC2: No response. Please address this item on plan. END OF COMMENTS