HomeMy WebLinkAbout269209_5_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101104932 - 33
PROJECT ADDRESS:
5117 1/2 W Morningside Ave
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
10/13/2020
INITIAL REVIEW
11/5/2020
EXPIRATION
4/11/2021
RECHECKS:
1.1/7/2021
PROJECT APPLICANT CONTACT PERSON:
2.6/4/2021
Leon Tran
3.8/17/2021
TEL:
(714)418-6604
FAX:
VALUATION: $75,000.00
EMAIL:
trandesign7@gmail.com
FLOOD ZONE: A-0602320143J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Police Department approval on the corrected/final set of drawings (647-5840).
-Public Works Agency approval (647-5039).
- School District Compliance Certificate; and a copy of the building permit application, signed by
the plan check engineer, shall be required by the School District to verify the scope of the work.
-Grading Permit. Application is made through the Building Safety Division (647-5800) and the
plan review is by the Public Works Agency (647-5039).
Elevation Certificate is provided: Please provide the following –
Section A2: Please use half address (5117- ½ W. Morningside Ave) for the proposed ADU.
Section A8 and A9: Please complete all information; use ‘N/A’ if not applicable.
Completed Elevation Certificate should be reproduced onto the plan.
Sheet A1:
Referenced Detail 21/SD1: Please revise detail to show 5/8” type ‘X’ on the inside of wall; 7/8” stucco over the 2 layers of type D building paper over plywood sheathing.