HomeMy WebLinkAbout278737_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101107761 PROJECT ADDRESS: 1148 W Civic Center Dr PLAN CHECK ENGINEER: Le, TungTEL:714 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/24/2021 INITIAL REVIEW 10/6/2021 EXPIRATION 2/20/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ali Sahabi 3. TEL: (323)605-0000 FAX: VALUATION: $50,000.00 EMAIL: engineering@optimumseismic.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.Approval and Instruction All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039). Sheet A-0: On the plan, please specify occupancy groups (R-2 / S-2). On the plan, please clearly specify the proposed seismic force-resisting system. Structural Observation Program: Please complete the Declaration By Owner by provide signatures and date. Please provide engineering evaluation report with finding and recommendation for the proposed retrofit. Sheet A-1 & A-2: For clarity, please provide Title Block for the floor plans (First Level; Second Level). Sheet S-1: 4”x1/4” PL – Please clarify what is the abbreviation of “PL”. Is it 4” x 1/4” steel strap plate? Please clarify on plan. Please clarify what is “SCC” abbreviation. On the plan, please provide existing floor diaphragm specification. State all assumption. Sheet SD-1: Detail 9: Please provide calculation and details to show shear transfer of diaphragm loads to steel column. Detail 9, 10, 12: Please revise details to show the A35 connected to the solid blockings or floor joists; attached to plywood appeared insufficient. Detail 10 & 12: Please revise detail to show transfer of lateral loads from second floor wall to floor diaphragm to shear wall below. Structural calculation: Irregularities: The seismic forces shall be increased 25% for the following elements of the seismic force-resisting system: Connections of diaphragms to vertical elements and to collectors Collectors and their connections, including connections to vertical elements, of the seismic force-resisting system. Please revise calculation and plan as necessary. Calculation: Load path – please specify existing diaphragm specification. Steel Cantilevered columns modeled in Risa: The column should be model individual (single post) and fixed at bottom. Please revise calculation and plan accordingly. It’s appeared that transfer of diaphragm loads into two steel columns would be unfeasible (insufficient). Steel moment frame(s) or additional cantilever columns are required.