HomeMy WebLinkAbout276866_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101107179
PROJECT ADDRESS:
3605 S Bristol St Unit# B
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/8/2021
INITIAL REVIEW
7/18/2021
EXPIRATION
1/4/2022
RECHECKS:
1.09/06/2021
PROJECT APPLICANT CONTACT PERSON:
2.
Mark Fernandez
3.
TEL:
(909)248-3172
FAX:
VALUATION: $180,000.00
EMAIL:
mark@goldenpropertydevelopment.com
FLOOD ZONE: X-0602320259J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTSPlease return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Public Works Agency approval (647-5039)Sheet G00.0. Indicate type of construction. (CBC Chapter 6)Sheet G00.0. Indicate Occupancy Group. (CBC Chapter 3)Fill out the disabled access compliance documentation form. Clarify in the form and on plan if the existing accessible path of travel fully or partially complies with 2019 CBC and show if any proposed design, detail and location of improvement in compliance with accessibility requirements along the accessible path of travel in accordance with CBC Section 11B-202. Note: Return the filled form at the next plan check submittal.PC2: The form is not filled and returned by the architect in record. If the adjusted cost of construction is below threshold value, the 20% minimum of adjusted cost of construction applies to this project.Completely fill out, sign, date, and clarify in the form where and how to comply the accessible path of travel upgrades by the licensed architect in record.Remove “for reference only” from the site plan title.Identify all non-compliant accessible elements on the site plan and provide compliance details and make cross-reference to the site plan. Plans and details shall match disable access compliance form section 6 and section 7.Note that incomplete or incorrect information in the form and plans may cause the project rejection.END OF COMMENTS