Loading...
HomeMy WebLinkAbout277041_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101107231 PROJECT ADDRESS: 3321 S Bristol St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, M, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/21/2021 INITIAL REVIEW 7/31/2021 EXPIRATION 1/17/2022 RECHECKS: 1.10/2/2021 PROJECT APPLICANT CONTACT PERSON: 2. Cindy Ramirez 3. TEL: (213)858-7896 FAX: VALUATION: $700,000.00 EMAIL: cindy@permitadvisors.com FLOOD ZONE: X-0602320259J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A0.0: Drawing Index: Plumbing, Mechanical and Electrical are under a separate review and approval – Please omit MEP on the Drawing Index. 2nd Review Comment: The G’s sheets were moved to the back of the plan set. Please place plan sheets in order as listed under the Drawing Schedule/Index. Sheet SP1.0: ON the plan, please show/provide an accessible route from the public sidewalk to the building primary entrance. 2nd Review Comment: Response was complete. On the plan, please clearly show/provide the accessible route from the public sidewalk to the building entrance. Sheet G1.4 through G1.6: 2nd Review Comment: Sheets G’s and X1.0 were not placed in order as listed under the Sheet Index. Please coordinate plan submittal plan sets. Sheet A5.2: Detail 10: Please revise detail to show spout locations in compliance with Section 11B-602. Show dimensions on plan. 2nd Review Comment: Response was incomplete. Please revise detail to be legible, and show spout minimum and maximum height for standing person (38” minimum – 42” maximum). (11B-602.7)