HomeMy WebLinkAbout280064_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101108168
PROJECT ADDRESS:
324 W Fourth St Unit# A
PLAN CHECK ENGINEER:
Le, TungTEL:714
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
A-2, B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
10/5/2021
INITIAL REVIEW
10/21/2021
EXPIRATION
4/3/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Samuel Ruiz
3.
TEL:
(714)675-3849
FAX:
VALUATION: $10,000.00
EMAIL:
samyfilm@gmail.com
FLOOD ZONE: X-0602320276J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
Approval and General Information
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- County of Orange Health Department approval on the corrected/final set of drawings ((714)433-6000)Sheet A-1: Important!Public works encroachment permit is required from Public Works prior to resubmitting plan back to Building Safety for recheck. On the plan, please provide occupant for the outdoor dining area. Sheet A-2: Doors/Gates: Please show/provide a level landing and maneuver spaces on both sides of the doors/gates. Maneuver clear floor space shall comply with 11B-404.2.4. On the pull side, provide 60” clear, measured on the direction of travel, with 24” clear from the door strike edge. On the plan, please specify door/gate sizes. Door/gate shall comply with 11B-404. On the plan, please specify door/gate hardware. Hardware shall comply with 11B-404.2.7. Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with Section 11B-309.4. Operable parts of such hardware shall be 34” minimum and 44” maximum above the finish floor or ground. Door/gate shall be provided with a smooth surface on the push side within the 10” of the finish floor or ground, measured vertically. (11B-404.2.10)Doors/gates shall be sizes for total occupant loads from inside of the building + outdoor dining area. Detail 6: 2x2x16 GA. Steel called was not consistent with structural plans. Please revise detail accordingly. For consistency, please reference to structural plan and details for structural information. Section 2: Please show minimum distance (separation distance) between new canopy and existing building. Structural: The structural will be covered with roof cover – Please design the steel canopy with wind loads. Please provide building separation between new canopy and existing structure to prevent lateral drifting damage to the existing building face.