Loading...
HomeMy WebLinkAbout274849_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101106607 PROJECT ADDRESS: 100 S Elk Ln PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: I A, III B, SPK OCCUPANCY CLASSIFICATION(S): A-2, A-3, B, R-2, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/7/2021 INITIAL REVIEW 5/25/2021 EXPIRATION 11/3/2021 RECHECKS: 1.09/29/2021 PROJECT APPLICANT CONTACT PERSON: 2. Lisa Zoscak 3. TEL: (949)338-4189 FAX: VALUATION: $180,000.00 EMAIL: lisa@aquatictechnologies.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Health Department approval. PLAN CHECK COMMENTS STRUCTURAL All structural drawings and structural calculation shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. Provide structural calculation and detail for the wall framing and anchorage to the podium slab of the pool enclosure walls, which are shown on the landscape plan: (CBC, ASCE 7-16) Detail C/LC.7. PC2: The structural design refers to structural detail 13/1SL-2.0. Provide structural calculation to verify structural design and anchorage. Detail A/LC.19. Detail A/LC.11. Detail A/LC.13. PC2: The structural design refers to structural detail 13/1SL-2.0. Provide structural calculation to verify structural design and anchorage. Detail A/LC.16. PC2: Detail 5/1SL-2.0. Clarify the CMU wall. Plan shows 8”, but calculation requires 12” nominal thickness. Please clarify on plan and calculation to be consistence. END OF COMMENTS