Loading...
HomeMy WebLinkAbout280744_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108370 PROJECT ADDRESS: 1700 E Carnegie Ave Unit# 100 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/25/2021 INITIAL REVIEW 11/6/2021 EXPIRATION 4/23/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Sahar Abbasnia 3. TEL: (949)788-40511051 FAX: VALUATION: $400,000.00 EMAIL: sabbasnia@waremalcomb.com FLOOD ZONE: X-0602320278J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS Required Approval and General Instruction All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Orange County Fire Authority (714) 573-6100Sheet I0.1: Job address: Please include the suite 100 for the subject project. Apply to all plan sheets. On the plan, please specify the total floor area of the exiting suite 100; separately list for each occupancy. Sheet Index: Electrical and Mechanical – Please specify “under a separate review”. Building & Code Information: Occupancy – please include S-1 for the storage areas. Sheet I0.4: Referenced to the existing site plan and old permit numbers for the accessible path of travel was insufficient. Please provided updated site plan to show accessible parking spaces and accessible route in compliance with the current code (2019 CBC). Sheet I0.5: Storage areas: Please specify occupancy S-1 to be consistence with sheet I0.1; otherwise, occupancy separation is required between B and S-2. Existing from the office area should not exit through the storage/shipping area. Please provide door between the shipping area and exit corridor. Material Stock room: Please show second exit (egress path) for the material stock room. Office area: Please show/provide second exit (egress path) for the office area. Sheet I2.1: Please coordinate with comment above to provide door between existing shipping room and exit corridor. Wall legend and detail C/I6.1: Please specify metal stud size and spacing. Detail C/I6.1: Please specify fastener for wall brace to roof frames. Please provide/show accessible restrooms. Provide restroom plans and details to show compliance with Chapter 11B, Division 6 of the 2019 California Building Code. Where six or more toilet compartments are provided, or where the combination of urinals and water closets totals six or more fixtures, toilet compartments complying with Section 11B-604.8.2 shall be provided in the same quantity as the toilet compartments required to comply with Section 11B-604.8.1Sheet I4.1: Ceiling Legend: Please provide detail reference for the suspended ceiling and lighting fixtures. (End of Comment)