HomeMy WebLinkAbout280111_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101108188
PROJECT ADDRESS:
3601 W Moore Ave
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B, SPK
OCCUPANCY CLASSIFICATION(S):
B, F-1, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
10/6/2021
INITIAL REVIEW
10/22/2021
EXPIRATION
4/4/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Morgan Schuff
3.
TEL:
(949)433-1760
FAX:
VALUATION:
EMAIL:
mschuff@culpco.com
FLOOD ZONE: X-0602320258J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
Approval Required and General Instruction
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet T.1: Reminder: Please submit plan to Fire Department for review and approval of the proposed CO2 tank. On the plan, please provide the following information: Applicable Codes: 2016 CBC, CMC, CEC, CPC. Building Occupancy groups (B, F-1, S-1)Scope work under this permit application: New CO2 tank and Vaporizers and concrete supporting pad.Structural plan and calculation: Structural calculation: Please revise calculation limit soil bearing pressure to 1500 psf. Revise plan as necessary. 2nd Review Comment: Please provided revised calculation with soil bearing pressure of 1500 psf. Otherwise, provide soil report if using higher soil bearing pressure value. Structural calculation: Please provide anchorage calculation for when tank is empty (tare weight). Revise plan as necessary. Foundation plan: Please show dimension (distance) measure from the centerline of the tank to the edge of concrete pad; and to the edge of the adjacent required footing supporting the vaporizers. 2nd Review Comment: Response was insufficient. Please revise pad/foundation to show tank placed on center of 8’-9” x 8’-9” concrete pad; otherwise, show dimensions required above. Currently it’s not placed on the center of the 8’-9”x12’’0” as stated in the response.