HomeMy WebLinkAbout279372_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101107965 PROJECT ADDRESS: 709 S Hickory St Unit# 2 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/15/2021 INITIAL REVIEW 9/24/2021 EXPIRATION 3/14/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Araceli Maciel 3. TEL: (714)285-1121 FAX: VALUATION: $44,100.00 EMAIL: aramaci65@gmail.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet A-2: Building Section referenced to sheet S-2 was not applicable. Please reference to sheet A-3 for building section. Per City Ordinance, provide a cooking facility with appliances, foodpreparation counter and storage cabinets. One-hour fire-rated wall is required for exterior wall located less than 5-ft from the property line. On the plan, please clearly show/designed one-hour wall and provide construction detail. Wall separating two sleeping unit shall be protected with one-hour fire-rated wall. Wall shall extended from floor/slab to the underside of roof sheathing. Please provide detail and clearly cross-referenced onto the plan. Sheet U-1: Please show/provide carbon monoxide alarm in the JADU and in existing house at the hallway giving access into each bedroom. Sheet S.1: Wall between existing and new addition: Please show/provide shear wall. Design wall for existing + new loads.