HomeMy WebLinkAbout277041_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101107231
PROJECT ADDRESS:
3321 S Bristol St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
B, M, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/21/2021
INITIAL REVIEW
7/31/2021
EXPIRATION
1/17/2022
RECHECKS:
1.10/2/2021
PROJECT APPLICANT CONTACT PERSON:
2.
Cindy Ramirez
3.
TEL:
(213)858-7896
FAX:
VALUATION: $700,000.00
EMAIL:
cindy@permitadvisors.com
FLOOD ZONE: X-0602320259J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet A0.0: Drawing Index: Plumbing, Mechanical and Electrical are under a separate review and approval – Please omit MEP on the Drawing Index. 2nd Review Comment: The G’s sheets were moved to the back of the plan set. Please place plan sheets in order as listed under the Drawing Schedule/Index. Sheet SP1.0: ON the plan, please show/provide an accessible route from the public sidewalk to the building primary entrance. 2nd Review Comment: Response was complete. On the plan, please clearly show/provide the accessible route from the public sidewalk to the building entrance. Sheet G1.4 through G1.6: 2nd Review Comment: Sheets G’s and X1.0 were not placed in order as listed under the Sheet Index. Please coordinate plan submittal plan sets. Sheet A5.2: Detail 10: Please revise detail to show spout locations in compliance with Section 11B-602. Show dimensions on plan. 2nd Review Comment: Response was incomplete. Please revise detail to be legible, and show spout minimum and maximum height for standing person (38” minimum – 42” maximum). (11B-602.7)