Loading...
HomeMy WebLinkAbout281089_1_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108468 PROJECT ADDRESS: 501 E Memory Ln PLAN CHECK ENGINEER: Lee, WayneTEL:714 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/5/2021 INITIAL REVIEW 11/11/2021 EXPIRATION 5/4/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jay Blatter 3. TEL: (805)962-2746101 FAX: VALUATION:$75,000.00 EMAIL: jay@hbarchitects.com FLOOD ZONE:X-0602320163J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSThe applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714) 573-6100). - Police Department approval on the corrected/final set of drawings (647-5840). - Public Works Agency approval (647-5039).Show wall length on each wall segment on the site plan. Call out dimensions to verify total wall length match permit scope: 950 linear feet.Provide complete site plan to include entire 10 feet high fence. Part of the site plans are missing on the submitted plan.Identify property lines enclosing the entire property on the site plan.Operable parts of door hardware shall be 34” minimum and 44” maximum above the finish floor or ground. (CBC 11B-404.2.7)Provide enlarged floor plans and details for the proposed accessible pedestrian gate: The front approach level area shall have a length in the direction of door swing of at least 60” and the length opposite the direction of door swing of 48” as measured at right angles to the plane of the door in the closed position. (CBC 11B-404.2.4.1 & Table 11B-404.2.4.1) Recessed doors maneuvering clearances for forward approach shall be provided when any obstruction within 18” of the latch side at an interior doorway, or within 24” of the latch side of an exterior doorway, projects more than 8” beyond the face of the door, measured perpendicular to the face of the door or gate. (CBC 11B-404.2.4.3 & Figure 11B-404.2.4.3 (a)) Provide clear space of 12” past strike edge of the door on the opposite side to which the door swings if the door is equipped with both a latch and a closer. (CBC Figure 11B-404.2.4.1(c))Thresholds shall be ½” high maximum. Raised thresholds and changes in level at doorways shall comply with CBC Section 11B-302 and 11B-303. (CBC 11B-404.2.5)Provide 10 feet tall fence wall architectural design and elevations.STRUCTURALProvide structural calculation and details to design fence wall framing, fence wall footing and gate footing. Plans and details shall be stamped, dated and signed by the licensed design professial.END OF COMMENTS