HomeMy WebLinkAbout282102_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108810 PROJECT ADDRESS: 501 E Washington Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/7/2021 INITIAL REVIEW 1/17/2022 EXPIRATION 6/5/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Andrew Chu 3. TEL: (626)731-0467 FAX: VALUATION: $160,000.00 EMAIL: andyouchu@gmail.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. All drawings and supporting documents shall be prepared, stamped, and signed by the registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1). Remove sheet E-1, E-2, P-1, P-2, M1 and M2 sheets or add a note on plan: “For reference only”. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). Sheet A-1. Show total interior remodel square footage in the scope of work description on plan. Sheet A-1. Provide more detailed description for the extent of the scope of work under this building permit on plan. Sheet A-1. Add note to scope on plan: This permit does not include window change-out. Sheet A-3. Show proposed new air condition unit on the site plan. Sheet A-3/1. Transpose hand-written notes into the drawing (e.g. engineer verification for removing non-load bearing walls). Sheet A-4. Provide a section or details showing the top and bottom anchorage for the interior non-bearing partitions. Show details for both perpendicular and parallel to ceiling or floor joists condition. Sheet A-4. Show carbon monoxide alarms outside all sleeping rooms and at each level on the floor plan. [2019 CRC R315]. Sheet A-4.Note on plan the carbon monoxide alarm requirements: CO alarms shall be “hardwire” and shall be equipped with battery backup. CO alarms shall be listed in accordance with UL 2034. CO alarms shall be listed in accordance with UL 2075. CO alarms shall be interconnected such that the activation of one alarm will activate all alarms in the individual dwelling unit. Sheet A-4. Provide dimensions on all NEW interior partitions on plan. Sheet A-4. Provide dimensions at the shower enclosure. Show minimum shower area of 1024 square inches finished dimension and ability to encompass a 30-inch diameter circle on plan. [2019 CPC 408.6] Sheet A-4. Note on plans: “Shower compartments and bathtubs with installed shower heads shall be finished with a nonabsorbent surface that exceeds to a height of not less than 6 feet above floor.” Sheet A-4. Show 22x30 inch clear access to the proposed furnace, located in the attic space. Provide a maximum of 20 feet from opening to furnace. END OF COMMENTS