HomeMy WebLinkAbout277652_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101107442 PROJECT ADDRESS: 2167 S Hathaway St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): F-2, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/4/2021 INITIAL REVIEW 9/9/2021 EXPIRATION 1/31/2022 RECHECKS: 1.11/09/2021 PROJECT APPLICANT CONTACT PERSON: 2. Michael Parr 3. TEL: (714)478-1889 FAX: VALUATION: $50,000.00 EMAIL: michael@tisbydesign.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSThis review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)PLAN CHECK COMMENTS:Sheet A00.40. On the site plan: Identify the location of the new exterior exit door, located in the back of the building.Provide bollards and minimum (door width +24”)wide x 5 feet long clearance with striping to provide required clearance of the door landing.Provide minimum 36” wide detectable warnings around the required landing area.PC2: On the (2) exterior doors on the east of the building, provide door landings, detectable warnings on the site plan, complying with the requirements in this comment. Note that door landings may cause restriping the existing parking layout, please contact Planning Division to approve the new parking layout before submitting to Building for recheck.ACCESSIBILITYSheet A00.41. Provide dimensions to show clearance in detail 1. Clearance around a water closet shall be 60 inches minimum measured perpendicular from the sidewall and 56 inches minimum measured perpendicular from the rear wall. A minimum 60 inches wide and 48 inches deep maneuvering space shall be provided in front of the water closet. §11B-604.3.1 (notes alone is not accepted). PC2: Plans are not clear. See redmarks on detail 1/A0.041 and A02.02.STRUCTURALPer sheet A12.01 detail 2, provide structural calculation, foundation plan, framing plan and details for restroom construction. Plans, calculation and details shall be stamped, signed and dated by the licensed engineer.PC2: No design is submitted. Fully and completely structural design, calculation and details are required.Provide gypsum ceiling assembly which is referred to detail 6/A12.01.PC2: Per your response to detail 2/A12.01. There is no assembly detail here. Specify type, thickness, attachment of the gypsum board in the ceiling detail. The structural design for ceiling and partitions are refer to correction item #28.Please separate plan check response page from structural calculation.END OF COMMENTS