Loading...
HomeMy WebLinkAbout282415_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108903 PROJECT ADDRESS: 901 W Civic Center Dr Unit# 400 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: II A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/15/2021 INITIAL REVIEW 1/12/2022 EXPIRATION 6/13/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Sean Nourani 3. TEL: (424)365-2070 FAX: VALUATION: $150,000.00 EMAIL: architectseannourani@outlook.com FLOOD ZONE: X-0602320144J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A0.0: Please specify on plan: Mechanical, Electrical and Plumbing are under separate plan review and approval. Sheet A1.0: Referenced detail 09/A1.1, stairway: Please provide detail to show contrasting stripe per Section11B-504.4.1. Reference detail 05/A1.1: Please revise detail to show wall mounted sign at 60” above finish grade, and the 80” clear should be measured to the lowest sign provided on the post. Accessible route shall be provided to the area of alteration. Please provide information for elevator to show compliance with Section 11B-407. Sheet A2.0: For clarity, please remove the clouds from plans. Apply to all plan sheets. Exit doorway that lead to the exit balcony shall be swinging in the direction of travel (outward) – door 1, door 3. Door open to exit balcony shall be fire-rated door (door 01, door 3). Entry #5: Exit shall not pass through the amenities room. Please create a corridor leading to the exit corridor. On the plan, please show location of drinking fountains. Drinking fountains shall be accessible to persons with disabilities. (11B-602) Sheet A2.2: Please provide detail support for new ceiling lighting fixtures. Detail shall be clearly cross-referenced onto the plan.Sheet A2.3: Fire-rated exit passageway: Please show the beginning of the protected exit passageway. Exit passageway shall be enclosed by fire-rated wall, ceiling, and opening protection (rated doors). Please coordinate and revise plan accordingly. Sheet A2.4: Fire-rated exit passageway: Please show the beginning of the protected exit passageway. Exit passageway shall be enclosed by fire-rated wall, ceiling, and opening protection (rated doors). Please coordinate and revise plan accordingly.Please revise plan to show exit doors swing in the direction of travel (toward the exit balcony). Entry #5: Exit shall not pass through the amenities room. Please create a corridor leading to the exit corridor.On the plan, please show/provide tactile exits at exit doorways. Sheet AD.1: Detail 11/AD.1: Please provide structural support and details for the glass wall. Provide calculation.