HomeMy WebLinkAbout281344_2_Corrections.docxSPC
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101108536
PROJECT ADDRESS:
3400 W Warner Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/10/2021
INITIAL REVIEW
12/3/2021
EXPIRATION
5/9/2022
RECHECKS:
1.1/11/2022
PROJECT APPLICANT CONTACT PERSON:
2.
Tatev Oganyan
3.
TEL:
(818)237-7867
FAX:
VALUATION:$25,000.00
EMAIL:
tatev@theoganyanagency.com
FLOOD ZONE:X-0602320258J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTSThe applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans
should be submitted to expedite the process.
- Public Works Agency approval (647-5039).Provide complete project address on the title block of each sheet.Show the complete Scope-of-Work on the plans per the permit application.PC2: Not available. Show description of scope on the first sheet of the drawings.
Add a note that the applicable Codes are: 2019 CBC, 2019 CEC, 2019 Energy Code, and City of Santa Ana Municipal Code
Show type of construction: VB and occupancy group: U on plan.Provide dimensions on plan for the proposed curb ramp and bottom landing on plan.PC2: Missing new curb ramp design on the pedestrian sidewalk (refer to keynote 14 on the site plan). Provide design on plan.On parallel curb ramps, detectable warnings shall be placed on the turning space at the flush transition between the street and sidewalk. Detectable warnings shall extend the full width of the turning space at the flush transition between the street and the sidewalk less than 2 inches maximum on each side §11B-247.1.2.2, §11B-705.1.2.2, Figure 11B-406.3.2PC2: Sheet A101. Missing new curb ramp design on the pedestrian sidewalk (refer to keynote 14 on the site plan). Provide design on plan.The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12 (8.33%). §11B-406.3.1, Figure 11B-406.3.2PC2: Sheet A101. Missing new curb ramp design on the pedestrian sidewalk (refer to keynote 14 on the site plan). Provide design on plan.A turning space 48 inches minimum by 48 inches minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be 1:48 maximum (2.083%). §11B-406.3.2PC2: Sheet A101. Missing new curb ramp design on the pedestrian sidewalk (refer to keynote 14 on the site plan). Provide design on plan.The cross slope of curb ramps shall be 1:48 (2.083%) maximum. §11B-406.5.7PC2: Sheet A101. Missing new curb ramp design on the pedestrian sidewalk (refer to keynote 14 on the site plan). Provide design on plan.Provide detectable warning details showing compliance with section 11B-705.1.1. E.g. dome size, dome spacing…Detectable warning surfaces shall be yellow and approximate FS 33538 of Federal Standard 595C. §11B-705.1.1.3.1Sheet A1.01. Extend the detectable warning across the entire width of the pedestrian walkway at the edge where adjoining the vehicular way.END OF COMMENTS