HomeMy WebLinkAbout282804_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109017 PROJECT ADDRESS: 2057 S Sycamore St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/4/2022 INITIAL REVIEW 1/25/2022 EXPIRATION 7/3/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Pedro Montenegro 3. TEL: (626)786-4359 FAX: (626)723-3059 VALUATION: $30,000.00 EMAIL: pedro@montenegroconsultants.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). Plans shall be signed and dated by the engineer of record. Apply to all sheets. Sheet A-2: Sidelight window D and bathroom window C and E – Please specify tempered glass. Sheet S-2: Roof framing – Please provide/show post supporting the 4x8 hips over the laundry room and bathroom, and reference detail 6/S3 to it. Detail 1/S-3: Please revise detail to provide minimum 8” concrete standoff between the exposed earth/ground and wood post. Unpermitted works to be removed adjacent to the existing garage Please provide floor for the existing garage. Show any work that will be reinstall to the original condition. Provide structural frames and details for existing garage where existing wall and roof frames were altered due to the illegal addition. Separate Mechanical, Electrical and Plumbing permits are required for the mechanical, electrical and plumbing works.