HomeMy WebLinkAbout282866_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109036
PROJECT ADDRESS:
1700 E Carnegie Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/5/2022
INITIAL REVIEW
1/31/2022
EXPIRATION
7/4/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Cheng-I Lin
3.
TEL:
(310)688-8439
FAX:
VALUATION: $25,000.00
EMAIL:
clin@nadelarc.com
FLOOD ZONE: X-0602320278J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.Please update the referenced code section on sheet AS-2 to 2019 version of CBC 11B. (e.g. 1129B is obsolete.)Sheet A0.00. Clarify the location of the 1st floor restroom to be altered on plan. The submitted plan shows a new restroom is added on the first floor. If this is the case, further review, plan check comments and additional plan check fee may apply.Provide existing floor plan prior to alteration.Clarify on plan if providing or altering any drinking fountains. New drinking fountains shall be accessible and design is required on plan.Provide accessible restroom signage design and details on plan.Entrances leading to toilet rooms and bathing rooms complying with 11B-603 Toilet and Bathing Rooms shall be identified by a geometric symbol complying with 11B-703.7.2.6 Toilet and Bathing Room Geometric Symbols.Ambulatory accessible compartment:Provide and identify at least one ambulatory accessible compartment for each sex on each level. Where six or more toilet compartments are provided, or where the combination of urinals and water closets totals six or more fixtures, toilet compartments complying with Section 11B-604.8.2 shall be provided in the same quantity as the toilet compartments required to comply with Section 11B-604.8.1 (11B-213.3.1)The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 17 inches minimum to 18 inches maximum from the side wall or partition, except that the water closet shall be 17 inches minimum and 19 inches maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in Section 11B-604.8.2 Ambulatory Accessible Compartments. Water closets shall be arranged for a left-hand or right-hand approach. (11B-604.2)Ambulatory accessible compartments shall have a depth of 60 inches minimum and a width of 35 inches minimum and 37 inches maximum. Revise dimensions on plan. (11B-604.8.2.1)Door shall be self-closing and shall not swing into the minimum required compartment area. Doors shall fully comply with 11B-604.8.2.2.Accessible lavatoriesProvide accessible lavatory design and detail showing fully compliance with 11B-606.END OF COMMENTS