HomeMy WebLinkAbout282920_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109051
PROJECT ADDRESS:
1015 S Fairview St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
M
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/6/2022
INITIAL REVIEW
2/16/2022
EXPIRATION
7/5/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Alfredo Rodriguez
3.
TEL:
(909)374-2597
FAX:
VALUATION: $30,000.00
EMAIL:
aedengineering@yahoo.com
FLOOD ZONE: X-0602320256J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet A-1: Plan shall be stamped, signed and dated by the architect of record. Apply to all sheets. Detectable warning (truncated dome) are not required in the parking lot at the access aisle. Please coordinate and revise plans. Accessible route connection from the public sidewalk to the building: Please provide accessible path through the landscape area (48” cut through) – connection at the driveway approach is insufficient. Detectable warning will required at the cut-through landscape area. Provide detail for the new concrete curb ramp. Provide detail for truncated dome. Sheet A-3: On the plan, please clearly show / identify the location of the roof repair. On the roof framing plan, please clearly show which headers are to be removed and replace. Provide lateral resisting elements along the covered walkway. Trash enclosure: Please imprint the trash enclosure onto the plan. Taped-on are not allowed. Provide construction details for CMU trash enclosure walls and footing. Trash enclosure: Please clarify whether there is roof cover over the trash enclosure? If roof cover is provided, the wall adjacent to the property line must be extended to the underside of roof. Provide structural calculation and details for CMU wall exceeding 6-ft. height.
(End of Comment)