PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109112
PROJECT ADDRESS:
1010 N Tustin Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
UnKnown (requires applicant to identify)
OCCUPANCY CLASSIFICATION(S):
UnKnown(requires applicant to identify)
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/13/2022
INITIAL REVIEW
2/24/2022
EXPIRATION
7/12/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Kenny Sommer
3.
TEL:
(714)693-2277
FAX:
VALUATION:$500,000.00
EMAIL:
KSommer@oed-inc.com
FLOOD ZONE:X-0602320164J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840).
- Public Works Agency approval (647-5039).Provide a site plan. Submit fully dimensioned plot plan including:Show all property lines of record on the site plan. Location of all structures on the site.North arrowAccessible parking stalls (CBC 11B-208, 11B-502)Provide Building Info on the cover sheet T1:Occupancy type (CBC Ch. 3)Construction type (s) (CBC Ch.6)Total area and aggregate areasNumber of storiesFire Sprinkler – typeShow the complete Scope-of-Work on the plans per the permit application. Plan review is subject to the Scope-of-Work on the permit application and any work not part of the Scope-of-Work (Project Description) shall be deleted or marked as “Existing”.Please show orientation of the north arrow on the structural framing plan.Show dimensions of the new platform on sheet S102.All structural plans shall be stamped, signed and dated by the structural engineer in record.Please show page number on each page of the structural calculation.Please update ENERCALC calculation in accordance with 2019 CBC.(SAP2000)-Cross-reference the analysis into truss member on the framing plan. Specify location, span and member size. In SAP2000 analysis, provide nodal and member diagram for geometry layout. Provide an explanatory calculation for the loading to verify load input.Please show in SAP2000 analysis that the analysis is in accordance with 2019 CBC. Show location of the compliance code. Which page?The SAP2000 shows total 86 pages, however, only 18 pages are submitted. Please clarify.Provide equipment specification on each unit on plan to verify structural calculation. Please do not refer them to other plan which is not part of this submission.Each unit has different anchorage location, weight and dimensions. Provide calculation for all rooftop unit anchorage. Missing AH25, AH26, AH30 and AH31.Please justify the existing building lateral support system is adequate to support additional lateral force from the equipment units.Sheet S102. Cross-reference anchorage and control details into mechanical schedule.END OF COMMENTS